Al. 1 Black-Out
Al. 2 Smoke probe
Al. 3 Hot Smoke
Al. 4 Faulty Aspirator
Al. 5 Failed Ignition
Al. 6 No Pellet
Al. 7 Thermal Security
Al. 8 No Depression
Al. 1 Black-Out

Power supply interrupted during working phase

Check:

  • If the power supply is missing only at the stove, check the power cable and the fuses at the main switch.

How to reset

  • Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.
Al. 2 Smoke probe

Flue gas probe failure


 

How to reset:

  • Contact local customer support
Al. 3 Hot Smoke

The heater is turned off for security reason, the flue gas temperature reached the safety limits.

Check:

  • Clean the stove carefully, pay attention to the inspection compartment where the exhaust fan is situated.
  • Check if air intake or chimney are clogged;

How to reset:

  • Increase the working power of the air fan; 
  • If the error persists, contact local Customer Support.
Al. 4 Faulty Aspirator

Smoke fan failure / Anomaly in the pressure switch / Smoke fan circuit interrupted


Check:

  • Clean the stove carefully, pay attention to the inspection compartment where the exhaust fan is situated.

 

How to reset

  • Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.
Al. 5 Failed Ignition
The stove fails to turn on
The security alarm appears on the display and the heater shuts down.

Check:
  • Check if the pellet used is certified according to ISO EN 17225-2 class A1;
  • Make sure to use only dry pellet. To ensure good combustion, pellets must be stored in an area that is free of humidity.
  • Check if the burn-pot is clean and not damaged. The burn pot must be correctly positioned in its seat;
  • Empty the ash drawer, clean the inspection compartment, check if there primary air inlet or flue pipe are clogged;
How to reset
  • Clean the burn-pot of any residues before starting the new ignition;
  • Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.
Al. 6 No Pellet

No pellets in hopper / High humidity of pellet / Pellet extra long


How to reset:

    • Refill pellet hopper;
    • Clean the burn-pot. Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.
Al. 7 Thermal Security
The pellet tank temperature has exceeded the imposed limit.
The safety thermostat is activated and the operation of the heater is interrupted for safety reason.

Check:
  • Let the stove cool and check the pellet tank;
  • Check if the space where the stove is installed is correctly ventilated;
How to reset:
  • The thermal security thermostat can be found below the power cable. Unscrew the black cap that covers a white button, press the button until hearing a click. At this point the thermostat is reset.
  • Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.
Al. 8 No Depression
Lack of draft in the combustion chamber

What to do:
  • Clean the stove carefully;
  • Make sure that inspection compartment is placed correctly and closed tightly;
  • Check if the flue pipe is clogged;
  • Check if the air inlet is free of any obstacle;
  • Control the speed of the smoke fan, if it is remarkably low, contact local customer support;
How to reset:
  •  Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.
Attention After having found and solved the cause of the alarm, empty the burn-pot before the new ignition