{"id":1404,"date":"2020-09-25T10:18:20","date_gmt":"2020-09-25T10:18:20","guid":{"rendered":"https:\/\/www.caldoungaro.it\/wp_ass\/?page_id=1404"},"modified":"2020-11-25T10:06:46","modified_gmt":"2020-11-25T10:06:46","slug":"c7en","status":"publish","type":"page","link":"https:\/\/www.caldoungaro.it\/wp_ass\/t7en\/c7en\/","title":{"rendered":"c7"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1404\" class=\"elementor elementor-1404\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-88e03a1 elementor-section-content-top elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"88e03a1\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-narrow\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a2c79c1\" data-id=\"a2c79c1\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ab0188b elementor-widget elementor-widget-image\" data-id=\"ab0188b\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"200\" src=\"https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-768x200.jpg\" class=\"attachment-medium_large size-medium_large wp-image-948\" alt=\"\" srcset=\"https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-768x200.jpg 768w, https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-300x78.jpg 300w, https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-1024x266.jpg 1024w, https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-1536x400.jpg 1536w, https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-830x216.jpg 830w, https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14-230x60.jpg 230w, https:\/\/www.caldoungaro.it\/wp_ass\/wp-content\/uploads\/2020\/09\/imm14.jpg 1780w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bcfadc elementor-tabs-view-vertical elementor-widget elementor-widget-tabs\" data-id=\"0bcfadc\" data-element_type=\"widget\" data-widget_type=\"tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-tabs\">\n\t\t\t<div class=\"elementor-tabs-wrapper\" role=\"tablist\" >\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1231\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1231\" aria-expanded=\"false\">SOND H2O<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1232\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1232\" aria-expanded=\"false\">HOT TEMP<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1233\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1233\" aria-expanded=\"false\">SOND FUMI<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1234\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1234\" aria-expanded=\"false\">PUL BRAC<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1235\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1235\" aria-expanded=\"false\">NO WOOD<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1236\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1236\" aria-expanded=\"false\">NO DEP<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1237\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1237\" aria-expanded=\"false\">HOT PELL<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1238\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1238\" aria-expanded=\"false\">NO RETE<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1239\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"9\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1239\" aria-expanded=\"false\">PRESS H2O<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-12310\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"10\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-12310\" aria-expanded=\"false\">SIC OFF<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-12311\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"11\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-12311\" aria-expanded=\"false\">HOT H2O<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t<div class=\"elementor-tabs-content-wrapper\" role=\"tablist\" aria-orientation=\"vertical\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1231\" aria-expanded=\"false\">SOND H2O<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1231\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1231\" tabindex=\"0\" hidden=\"false\"><span style=\"text-decoration: underline;\"><strong>High water temperature in the thermostove<\/strong><\/span>\n<br><br>\n<strong>Check:<\/strong>\n<ul>\n \t<li dir=\"ltr\"><em>Verify proper water flow in the system: if it is zoned, make sure to have at least one zone open; check the external ciculation pump, room thermostats (if present);<\/em><\/li>\n \t<li><em>If more than one heat generators are connected to the heating system, control if they produce excessive heat;<\/em><\/li>\n \t<li dir=\"ltr\"><em>Verify if the water pressure is in the limits indicated in the description of &#8220;Press H2O&#8221;.<\/em><\/li>\n \t\n<\/ul>\n<strong>How to reset:<\/strong>\n<ul>\n \t<li dir=\"ltr\"><em>The thermal security thermostat can be found below the power cable. Unscrew the black cap that covers a white button, press the button until hearing a click. At this point the thermostat is reset;<\/em><\/li>\n \t<li dir=\"ltr\"><em>Press and hold for 3 seconds the button ON to reset the alarm. Empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1232\" aria-expanded=\"false\">HOT TEMP<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1232\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1232\" tabindex=\"0\" hidden=\"hidden\"><span style=\"text-decoration: underline;\"><strong>The exhaust gas temperatue is over 280 \u00b0C<\/strong><\/span>\n<br> <br>\n<strong>Check:<\/strong>\n\n<ul>\n \t<li><em>Clean the stove carefully, pay attention to the inspection compartment where the exhaust fan is situated;<\/em><\/li>\n<li><em>Check if the flue pipe is clogged.<\/em><\/li>\n<\/ul>\n<br> \n<strong>How to reset:<\/strong>\n<ul>\n \t<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists with the clean chimney, contact local Customer Support.<\/em><\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1233\" aria-expanded=\"false\">SOND FUMI<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1233\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1233\" tabindex=\"0\" hidden=\"hidden\"><span style=\"text-decoration: underline;\"><strong>A problem in the circuit of flue gas probe<\/strong><\/span>\n<br> <br>\n<strong>How to reset:<\/strong>\n\n<ul>\n \t<li><em>Contact local Customer Support<\/em><\/li>\n<\/ul>\n<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1234\" aria-expanded=\"false\">PUL BRAC<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1234\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1234\" tabindex=\"0\" hidden=\"hidden\"><span style=\"text-decoration: underline;\"><strong>Failed ignition or  flame extinguishing<\/strong><\/span>\n<br><br>\n<strong>Check:<\/strong>\n\n<ul>\n \t<li><em>Make sure to have pelelts in the hopper. They must be dry and have an adequate dimension. Use only the pellets that meet requirements of the standard ISO 17225-2, class A1. The use of low quality compromises the running of your appliance and can therefore lead to the termination of the guarantee;<\/em><\/li>\n<li><em>Take the burn pot out and clean it thoroughly to make sure all vent holes in the bottom are clear or the draft flow. Control if the burn pot is damaged or if some holes are melted;<\/em><\/li>\n<li><em>Make sure to have placed the burn pot correctly;<\/em><\/li>\n<li><em>Make sure that combustion chamber and inspection compartment are clean and closed tightly;<\/em><\/li>\n<li><em>Check if the flue pipe or air intake are clogged. <\/em><\/li>\n<\/ul>\n<br>\n<strong>How to reset:<\/strong>\n\n<ul>\n<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1235\" aria-expanded=\"false\">NO WOOD<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1235\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1235\" tabindex=\"0\" hidden=\"hidden\"><span style=\"text-decoration: underline;\"><strong>Pellet hopper is empty \/ \nA problem with exhaust gas probe.<\/strong><\/span>\n<br><br>\n<strong>Check:<\/strong>\n\n<ul>\n \t<li><em>Refill the pellets, they must be dry and have an adequate dimension;<\/em><\/li>\n<li><em>Take the burn pot out and clean it thoroughly to make sure all vent holes in the bottom are clear or the draft flow. Control if the burn pot is damaged or if some holes are melted;<\/em><\/li>\n<li><em>Verify if the ash box and inspection compartment are clean;<\/em><\/li>\n<li><em>Control if the chimney is clogged;<\/em><\/li>\n<\/ul>\n<br>\n<strong>How to reset:<\/strong>\n\n<ul>\n \t<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any leftover pellets and turn the heater on; <\/em><\/li>\n<li><em>If the error persists with the full pellet tank, contact local Customer Support.<\/em><\/li><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1236\" aria-expanded=\"false\">NO DEP<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1236\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"6\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1236\" tabindex=\"0\" hidden=\"hidden\"><span style=\"text-decoration: underline;\"><strong>Insufficient draught<\/strong><\/span>\n<br><br>\n<strong>Check:<\/strong>\n\n<ul>\n \t<li><em>Verify if the combustion chamber, ash box and inspection compartment are clean and properly closed;<\/em><\/li>\n<li><em>Control if the chimney is dirty or clogged;<\/em><\/li>\n<li><em>Check if the smoke fan is blocked or faulty: shut the thermostove down, wait until it is cooled, disconnect the power cable,\nremove the inspection box and check if there is a foreigh object in the smoke fan.<\/em><\/li>\n<\/ul>\n<br>\n<strong>How to reset:<\/strong>\n\n<ul>\n<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Empty the burner from any leftover pellets. Turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1237\" aria-expanded=\"false\">HOT PELL<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1237\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"7\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1237\" tabindex=\"0\" hidden=\"hidden\"><strong><span style=\"text-decoration: underline;\">High temperature in the pellet hopper \/ Faulty security thermostat<\/span><\/strong>\n<br><br>\n<strong>Check:<\/strong>\n<ul>\n \t<li><em>Let the stove cool and check the pellet tank;<\/em><\/li>\n<li><em>Control if the flue pipe is clogged;<\/em><\/li>\n<\/ul>\n<br>\n<b>How to reset:<\/b>\n<ul>\n \t<li><em>The thermal security thermostat can be found below the power cable. Unscrew the black cap that covers a white button, press the button until hearing a click. At this point the thermostat is reset;<\/em><\/li>\n<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1238\" aria-expanded=\"false\">NO RETE<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1238\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"8\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1238\" tabindex=\"0\" hidden=\"hidden\"><span style=\"text-decoration: underline;\"><strong>No electricity for more than 1 minute<\/strong><\/span>\n<br><br>\n<strong>Check:<\/strong>\n<ul>\n \t<li><em>If the power supply misses only at the stove, check the power cable and the fuses at the main switch.<\/em><\/li>\n \t\n<\/ul>\n<br>\n<b>How to reset:<\/b>\n<ul>\n \t<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"9\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1239\" aria-expanded=\"false\">PRESS H2O<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1239\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"9\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1239\" tabindex=\"0\" hidden=\"hidden\"><strong><span style=\"text-decoration: underline;\">System pressure high \/ low<\/span>\n<\/strong>\n<br>The water pressure in cold system must be between 0,8 and 1,2 Bar.\n<br><br>\n<b>Check:<\/b>\n<ul>\n \t<li><em>To reduce the pressure, bleed a radiator or drain some water out of the system using a drain point; <\/em><\/li>\n \t<li><em>Verify if automatic water loading unit (if available) is faulty or not calibrated;<\/em><\/li>\n \t<li><em>If another heating appliance is installed, control if its filling tap is closed;<\/em><\/li>\n \t<li><em>If the pressure is low, open slowly water filling loop to increase the pressure. Close it when finished;<\/em><\/li>\n \t<li><em>Verify if there are water losses in the system.<\/em><\/li>\n<\/ul>\n<br>\n<b>How to reset:<\/b>\n<ul>\n \t<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Wait for 10 minutes, empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li>\n \t\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"10\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-12310\" aria-expanded=\"false\">SIC OFF<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-12310\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"10\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-12310\" tabindex=\"0\" hidden=\"hidden\"><p dir=\"ltr\"><span style=\"text-decoration: underline;\"><strong>The water temperature in the thermostove has exceeded the imposed limits, the water security thermostat is enabled<\/strong><\/span><\/p>\n\n<br> <br><b>Check:<\/b><\/p>\n\n<ul>\n \t<li><em>Verify proper water flow in the system: if it is zoned, make sure to have at least one zone open; check the external ciculation pump, room thermostats (if present);<\/em><\/li>\n<li><em>If more than one heat generators are connected to the heating system, control if they produce excessive heat;<\/em><\/li>\n<li><em>Verify if the water pressure is in the limits indicated in the description of &#8220;Press H2O&#8221;.<\/em><\/li>\n<\/ul>\n<br><b>How to reset:<\/b><\/p>\n\n<ul>\n \t<li><em>The thermal security thermostat can be found below the power cable. Unscrew the black cap that covers a white button, press the button until hearing a click. At this point the thermostat is reset;<\/em><\/li>\n<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li>\n<\/ul>\n<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"11\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-12311\" aria-expanded=\"false\">HOT H2O<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-12311\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"11\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-12311\" tabindex=\"0\" hidden=\"hidden\"><p dir=\"ltr\"><span style=\"text-decoration: underline;\"><strong>Water temperature is over 92\u00b0C<\/strong><\/span><\/p>\n<br>\n<p dir=\"ltr\"><b>Check:<\/b><\/p>\n\n<ul>\n \t<li><em>Verify proper water flow in the system;<\/em><\/li>\n<li><em>Check if the circulation pump is blockd\n<\/em><\/li><\/ul>\n<br>\n<p dir=\"ltr\"><b>How to reset:<\/b><\/p>\n\n<ul>\n \t<li><em>Press and hold for 3 seconds the button ON to reset the alarm. Empty the burner from any unburnt pellet and turn the heater on. If the error persists, contact local Customer Support.<\/em><\/li><\/ul><\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92febd8 elementor-widget elementor-widget-text-editor\" data-id=\"92febd8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>scheda: Micronova 2018<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-40c506f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"40c506f\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a2d62c5\" data-id=\"a2d62c5\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-59ca997 elementor-widget elementor-widget-html\" data-id=\"59ca997\" data-element_type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<form>\n<input type=\"button\" value=\"back\" \nonClick=\"history.go(-1);return true;\" \nname=\"button\">\n<\/form>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>SOND H2O HOT TEMP SOND FUMI PUL BRAC NO WOOD NO DEP HOT PELL NO RETE PRESS H2O SIC OFF HOT H2O SOND H2O High water temperature in the thermostove Check: Verify proper water flow in the system: if it is zoned, make sure to have at least one zone open; check the external ciculation &#8230;.&nbsp;&nbsp;<a class=\" default\" href=\"https:\/\/www.caldoungaro.it\/wp_ass\/t7en\/c7en\/\">Read More<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":1398,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","footnotes":""},"class_list":["post-1404","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/pages\/1404","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/comments?post=1404"}],"version-history":[{"count":62,"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/pages\/1404\/revisions"}],"predecessor-version":[{"id":2446,"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/pages\/1404\/revisions\/2446"}],"up":[{"embeddable":true,"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/pages\/1398"}],"wp:attachment":[{"href":"https:\/\/www.caldoungaro.it\/wp_ass\/wp-json\/wp\/v2\/media?parent=1404"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}